Programmable Thermostat W1209 Operating Manual
1. Description
The programmable thermostat is designed to control the temperature in the range from -50°C to +110°C. It can operate together with a heater or a cooler. The programmable thermostat is equipped with a three-digit LED display, a relay activation LED indicator, large control buttons, a connector for an external temperature sensor, terminals “K0/K1” for load connection, and “+I2V/GND” for powering the thermostat board. The liquid crystal screen shows the current measured temperature.
The thermostat features a three-digit indicator (HS310281K), displaying temperatures from -50°C to +110°C. Temperatures from -10°C to -50°C and from 100°C to 110°C are displayed without a decimal fraction, which is sufficient for household use. The board also includes a red LED “LED1” that duplicates the relay activation.
The thermostat supports two modes of operation: “C” (cooling) and “H” (heating). The mode is changed using three control buttons.
2. Main technical data and specifications
• Overall dimensions: 40 x 48 x 14 mm
• Temperature measurement and programming range: -50°C ... 110°C
• Measurement accuracy: 0.1 °C in the range from -9.9°C to 99.9°C; or 1.0°C outside this range
• Control accuracy: 0.1 °C in the range from -9.9°C to 99.9°C; or 1.0°C outside this range
• Hysteresis accuracy: 0.1 °C
• Hysteresis: 0.1...15°C
• Reading update time: 0.5 seconds
• Power supply voltage: 12 VDC
• Sensor: NTC 10K 0.5%, cable length 0.3 m, waterproof
• Maximum load current: 5A / 220VAC; 15A / 14VDC
• Ambient temperature: -10...60°C
• Ambient humidity: 20 - 85 %
• Current consumption: 30 mA
• Current consumption during relay operation: 65 mA
• Load connection method: electromagnetic single-channel relay (5A / 220VAC; 15A / 14VDC) (for higher loads, use a contactor or a solid-state relay with higher capacity)
3. Preparation for operation
1) Connect the 12V DC power source to the “+12V” (plus 12V) and “GND” (minus 12V) terminals.
2) Connect the load to the “K0” and “K1” terminals (connect in series with the power supply circuit of the controlled device). After supplying 12V power to the “+12V” and “GND” terminals, the liquid crystal display will show the current temperature measured by the external temperature sensor.
4. Setting and adjusting the desired temperature
To set the control temperature, briefly press the "SET" button, then use the “+” or “-” buttons to set the desired temperature, and press the "SET" button again, or do not press any buttons for 5 seconds.
5. Programming the W1209 thermostat
To enter programming mode, hold down the “SET” button for 5 seconds, then use the “+” or “-” buttons to select the parameter code (P0...P6) from the “Thermostat Menu” table. Next, to configure the parameter, press the “SET” button and use the “+” or “-” buttons to change the parameter value. To save the settings, press and hold the “SET” button, or do not press any buttons for 5 seconds.
Thermostat menu:
| Parameter code | Parameter description | Adjustment range | Default |
| P0 | Thermostat operating mode: Cooling/Heating | C/H | C |
| P1 | Hysteresis, °C | 0.1...15 | 2 |
| P2 | Upper limit of maintained temperature setting, °C | 120 | 110 |
| P3 | Lower limit of maintained temperature setting, °C | -50 | -50 |
| P4 | Temperature correction, °C | -7...+7 | 0 |
| P5 | Relay activation delay time (may differ from the selected value within ±50%), min. | 0...10 | 0 |
| P6 | Upper cut-off temperature limit (overheat protection), °C | OFF or ON (when ON from 0°C to 110°C) | OFF |
| P7 | Settings lock | OFF or ON (when ON, settings cannot be changed until P7 is set to OFF) | OFF |
| P8 | Factory reset | OFF or ON | OFF |
6. Indication
The LED display displays the following values:
- “LLL” – sensor not connected,
- “HHH” – temperature out of range (below -50°C or above 110°C),
- “—” exceeding the limits set in parameter P6
7. Resetting parameters to factory settings
To reset parameters to factory settings (default settings):
1) Turn off the power;
2) Press and hold the “+” and “-” buttons;
3) Supply power to the thermostat. The LED display will show “888”, after which the current temperature will be displayed.