We sincerely thank you for choosing our product. This is an important step towards your beauty. Before starting use, please carefully read this user manual. Keep it for reference at any convenient time.
.GEZATONE m1601 RF Lifting facial massager. Operating instructions
BEFORE USE
First of all, we express our sincere gratitude for using our product.
Before use, please read this manual carefully to ensure correct operation. Pay special attention to the chapter Safety Measures. For your own safety, carefully study this section before using the device.
Please keep this user manual; it may be useful to you in the future.
This device is intended for individual cosmetic use only; its application for therapeutic purposes is prohibited.
Causes of aging
Aging of the body is a complex process, and its mechanisms involve various biological and physiological aspects. Starting at the age of 25, there is a natural decline in the synthesis of collagen, a protein essential for skin elasticity and support. This process is accelerated by various factors, including stress, unfavorable environmental conditions, poor nutrition, chronic fatigue, exposure to ultraviolet radiation, tobacco smoking and other harmful habits, as well as sleep disturbances. Collectively, these factors lead to the loss of elasticity, skin tone, and the appearance of wrinkles.
In addition, with age the tone of muscle fibers decreases, which leads to deep wrinkles and deformation of the facial contour. Facial muscles play an important role in supporting the skin, and their loss of tone contributes to sagging and reduced firmness of the skin.
Previously, combating the aging process was limited to procedures available only in beauty salons. However, modern technologies provide new opportunities. For example, the multifunctional RF Lifting Gezatone m1601 device allows rejuvenating procedures to be carried out at home. This device offers operating modes for both the face and the body, giving users extensive opportunities to fight signs of aging of the skin and muscles. And thanks to the fact that the device includes modes for body care, you can also incorporate it into body contouring and slimming programs!
.ABOUT THE METHODS OF ACTION
The device for body and facial care combines the technology of radiofrequency thermotherapy with electrical muscle stimulation for muscle training and skin care.
RF lifting for the face
The action of the RF lifting device is based on the principle of radiofrequency exposure, leading to the heating of specific skin areas. This activates metabolism and blood flow in the dermal layer, stimulating the restoration of collagen fibers and giving the skin elasticity. Clinical studies demonstrate a long-term lifting effect in the treated areas.
RF lifting for the body
The radiofrequency procedure is also applicable for body contouring and cellulite reduction. The reduction of fat cells and stimulation of microcirculation improve skin texture and reduce fat mass. The effectiveness of the procedure is enhanced by the muscle stimulation function and the additional application of vibration and red light spectrum irradiation.
RF lifting for the face
The mechanism of action of the RF lifting device is based on the use of the radiofrequency range of electromagnetic radiation, which leads to the heating of certain skin areas. This process is carried out with high precision, targeting the dermis and subcutaneous fat layer while bypassing the upper epidermis. As a result of the thermal effect of radiofrequency, metabolic processes are stimulated, and blood circulation and metabolism in the dermal layer are enhanced.
Upon reaching a certain temperature, the collagen regeneration process is initiated. This restores skin elasticity and reduces wrinkles due to increased density of collagen fibers. As a result of the procedure, a noticeable improvement in skin texture is observed, manifested by firming and a lifting effect.
Clinical studies confirm the effectiveness of the RF lifting procedure in skin rejuvenation by exerting the most favorable influence on the bodys internal reserves. The improvements achieved through this procedure are maintained for a long period in the treated areas.
RF lifting for the body
The radiofrequency procedure is an effective method for body contouring and combating cellulite. The heating effect of radio waves reduces fat cells and contracts collagen fibers, which improves skin texture and reduces the appearance of cellulite. The mechanism of this effect is based on increasing the temperature of subcutaneous areas for a short period. Moreover, radiofrequency heating of tissues activates microcirculation, promoting the removal of excess fluid from tissues and reducing swelling.
The use of the GEZATONE m1601 RF Lifting radiofrequency device ensures comprehensive skin rejuvenation, reduction of fat mass, and active elimination of excess fluid. The effectiveness of the procedure is further enhanced by the muscle stimulation function, which is recommended after the necessary number of radiofrequency sessions. This approach allows achieving maximum effect in the fight against cellulite and in improving skin condition.
Electrical stimulation of facial and body muscles
Electrical stimulation of facial and body muscles is based on the application of weak electrical impulses transmitted through nerve endings, causing muscle contractions. The intensity of these contractions depends on the parameters of the electrical impulses, including their amplitude and frequency. The principle of action of electrical muscle stimulation (EMS) devices consists in creating periodic muscle contractions, similar to the effect of regular physical exercises.
Regular electrical stimulation procedures help activate muscle function, leading to the strengthening of sagging body and facial areas. This allows effective management of excess weight and cellulite.
In addition, this massager includes additional functions such as vibration and red light spectrum irradiation. Vibration massage improves local blood circulation and lymphatic flow, promotes muscle relaxation, and increases the effectiveness of the device. The effect of red light on the skin stimulates its cells to produce collagen and elastin, which improves skin firmness and elasticity.
.APPEARANCE AND PACKAGE CONTENTS
1 RF electrodes (4 pcs.)
2 EMS electrodes (2 pcs.)
3 Red light spectrum emitters
4 Screen
5 Mode switching button
6 Intensity level adjustment button
7 Power on/off button (long press), pause/resume (short press)
8 Charging port
9 Charger
10 Charger connector
DEVICE CHARGING
Before the first use, the device must be fully charged. (Charge the device until the charging indicator turns off.)
Insert the adapter plug into the charging port and connect the adapter to a power outlet. The device will start charging immediately. After approximately 4 hours, the charger will emit a signal. This indicates that charging is complete.
PREPARATION FOR USE
1. Before the procedure, remove glasses and all jewelry (earrings, rings, bracelets, necklaces), and take out contact lenses from your eyes.
2. Remove makeup and cleanse the skin of the face from impurities. Before performing the body procedure, it is recommended to take a shower.
3. Apply an even layer of special gel to the treatment area, about 5 g (approximately the size of a nut).
.CONDUCTING THE PROCEDURE
1. Turn on the device. Remove the protective cap from the device. Press and hold the button until you hear a signal, then the screen will turn on. Immediately after switching on, you will feel vibration, and the red light spectrum emitters will light up. These functions are active in all operating modes of the device.
2. The device includes a total of 5 treatment programs, which you can select by pressing the M button. Each time you press the program selection button, the mode will change. Select the desired treatment mode.
3. Selecting the intensity level. After choosing the desired program, you need to set the intensity level (1-5). To do this, press the L button to select the most appropriate intensity level.
(!) Attention! For people with sensitive skin or using the device for the first time, it is recommended to set the device to level 1 and then choose the level suitable for your skin condition. For facial procedures, the intensity level should not exceed 4.
4. For correct procedure performance, the metal contacts of the device must be in close contact with the skin.
5. Gently move the device over the skin, following the schemes shown in the figure below.
6. If dryness is felt on the skin, apply more gel.
7. To pause, briefly press the power button once; to resume the procedure, briefly press the button again.
8. To turn off the device after completing the procedure, press and hold the button.
(!) Note: The device emits a sound signal after 3 minutes of use, indicating that the procedure is ending. If you want to finish the procedure, press and hold the power button for about 1 second to turn off the device. If you want to continue the procedure on other areas, apply the special gel to these areas before further treatment. Then repeat steps 2-5.
.RECOMMENDED TREATMENT SCHEMES FOR THE FACE
Facial contour and cheekbone area
Treatment time 3 minutes per side, total 6 minutes for both sides.
Apply the device to the cheek. Direct the device towards the cheekbone, moving rhythmically from bottom to top to the count of 1, 2.
Cheek area
The cheek procedure is divided into two phases. Treatment time 3 minutes per side, total 6 minutes for both sides.
Apply the device perpendicularly near the corner of the lips. Move the device rhythmically from bottom to top towards the cheekbone to the count of 1, 2 (with a one-second interval).
Perform these procedures alternately.
Apply the device vertically near the corner of the lips. Move the device rhythmically across from the corner of the lips towards the ear to the count of 1, 2 (with a one-second interval).
Chin
Treatment time 3 minutes.
Apply the device perpendicularly just under the chin. Move the device rhythmically in an arc to the left and right to the count of 1, 2 (with a one-second interval).
Abdomen (1)
Apply the device perpendicularly to the abdomen at a distance of about two fingers width from the navel. Move the device smoothly up and down from the rib to the lower abdomen, and then back towards the ribs.
Treatment time 3 minutes per area. Total 6 minutes for both sides.
Abdomen (2)
Apply the device perpendicularly to the abdomen in the waist area. Smoothly move the device towards the sides, working through the fat fold. If necessary, you may also treat the area below the navel using the same scheme.
Treatment time 3 minutes per area. Total 6 minutes for both sides.
Decollete area
Apply the device perpendicularly to the skin in the decollete area. Move the device smoothly from the center of the area towards the edges, as shown in the figure.
Treatment time 3 minutes per area. Total 6 minutes for both sides.
Shoulder
Apply the device to the middle of the inner side of the shoulder. Then move the device smoothly towards the armpit.
Buttocks
Apply the device perpendicularly to the skin, and move it smoothly from the center of the buttocks to the outer edge, working through the fat fold.
Treatment time 34 minutes per buttock, total 68 minutes for both sides.
Thighs
Apply the device to the inner thigh and then move it smoothly towards the groin.
Treatment time 34 minutes per side, total 68 minutes for both thighs.
.TREATMENT COURSE
Intensive one-month treatment course
An intensive one-month treatment course is recommended for people who have enough time to perform daily procedures.
| Treatment course | Recommended program | Main effects |
| Week 1 | Warm Up | Warming up the skin, which improves its tone, firmness, and elasticity. |
| Week 2 | Smoothing | Smoothing the skin the program restores smoothness, reduces the number of wrinkles. |
| Week 3 | Firming | Increasing muscle tone, correcting facial contour, reducing deep wrinkles. |
| Week 4 | Lift Up | Rhythmic stimulation of skin and muscles, a program for consolidating the achieved results. |
| Week 5 | Exercise | A program to maintain achieved results, procedures should be repeated 23 times per week to preserve and enhance the outcome. |
Starting from week 5, continue the procedures in training mode 23 times a week to reinforce the effect.
(!) Attention! If you feel excessive muscle fatigue, stop the procedures for 1 day to allow the skin to rest. Then you may continue the course.
Intensive two-month treatment course
Recommended for people who have enough time to perform procedures 23 times per week.
| Treatment course | Recommended program | Main effects |
| Weeks 12 | Warm Up | Warming up the skin, which improves its tone, firmness, and elasticity. |
| Weeks 34 | Smoothing | Smoothing the skin the program restores smoothness, reduces the number of wrinkles. |
| Weeks 56 | Firming | Increasing muscle tone, correcting facial contour, reducing deep wrinkles. |
| Weeks 78 | Lift Up | Rhythmic stimulation of skin and muscles, a program for consolidating the achieved results. |
Starting from week 9, continue the procedures in training mode 23 times a week to reinforce the effect.
CONTRAINDICATIONS AND USAGE RESTRICTIONS
Use by children is prohibited.
The device must not be used under the following conditions:
Presence of a pacemaker or other electronic implants.
Pregnancy, breastfeeding period.
Patients with acute diseases: tuberculosis, fever, infectious diseases, contact-transmissible diseases.
People with heart disease.
In the presence of scars.
People with eye diseases or undergoing treatment for eye diseases.
People with skin diseases, allergic dermatitis, or sensitive skin.
In case of redness and peeling of the skin caused by excessive tanning.
In the presence of acne and purulent inflammatory processes on the skin.
POSSIBLE MALFUNCTIONS AND TROUBLESHOOTING
| The device does not turn on | No charge. The power button was pressed weakly, not fully. |
| No stimulation sensation | Pause button pressed. Insufficient amount of gel. EMS power level too low. EMS elements not in contact with the skin. |
| Temperature does not increase No intense heating sensation. | The RF electrodes are not in contact with the skin. Low intensity level. |
| Heating sensation is too strong | The procedure lasts longer than 3 minutes on the same area. Insufficient amount of gel. |
| Works only a few minutes after charging the device. | Battery not sufficiently charged. Battery life has expired (about 3 years). |
DEVICE CARE
Make sure the device is turned off before cleaning.
If the thermostat becomes contaminated with skin oil or gel residue, it may misread skin temperature, which will quickly lead to wear. Therefore, it must be cleaned with a damp cloth after each use.
Do not rub the thermostat strongly to avoid damage. Since it is made of glass, strong rubbing or pressure may cause it to break or crack.
Do not wash the case in water. Wipe the case with a soft cloth slightly moistened with soapy water.
Do not wipe the device with alcohol, gasoline, nail polish remover, etc. This may cause damage and cracks on accessories, color changes, etc.
The protective cap must be washed if it becomes dirty.
TECHNICAL SPECIFICATIONS
Model: m1601
Dimensions: 240x230x65 mm
Weight: 500 g
Electrode material: stainless steel
Body material: acrylonitrile butadiene styrene, polycarbonate, rubber
Timer: auto shut-off function after 3 minutes.
Charger
Input voltage and current: AC 100240V, 50/60 Hz, 0.2A
Output voltage/current: DC 5.6V, 0.6A
Power consumption: about 3.5 W (during charging)
Adapter cable length: about 1.5 m
Battery
Rated voltage/capacity: 3.7 V, 560 mAh
Charging voltage: 4.2 V max.
Type: lithium-ion battery
Charging time: about 4 hours.
Weight: about 26 g.
Maximum operating time of the device after full charge: about 50 minutes of continuous operation.
User manuals for beauty and health devices and instruments |