The “Umnyi Vybor” UKE-AS2000M electric convector is a wall/floor heater rated at 2000 W with a STICH (needle) heating element, a mechanical thermostat, and a “Restart” function.



Umnyi Vybor UKE-AS2000M electric convector — FAQ and operating guidance

FAQ on operating the Umnyi Vybor UKE-AS2000M electric convector

What type of heating element is used in the “Umnyi Vybor” UKE-AS1000M/1500M/2000M convector?

A needle (STICH) heating element is installed. It provides fast warm-up and uniform convection with quiet operation.

How does the needle element differ from a cast heating element, and does the lineup include a cast type?

The needle element heats up faster but is sensitive to moisture; the cast heating element is more massive, quieter, and retains heat longer. The UKE-AS1000M/1500M/2000M models use the STICH needle element; cast heating elements are not provided in this lineup.

What are the power and heating modes of the UKE-AS2000M convector?

Rated power is 2000 W, with a single power mode. Temperature maintenance is performed by the mechanical thermostat.

Does the convector have a periodic shut-off timer?

No. Automatic on/off is controlled only by the thermostat when the set temperature is reached.

How does temperature maintenance work, and how do I set a “comfort” mode?

The mechanical thermostat cyclically switches heating on and off to maintain the set temperature. To fix a “comfort” level, preheat the room at MAX, then slowly reduce until the thermostat clicks—the unit will maintain that level.

What is the maximum adjustable room temperature?

The adjustment covers the typical domestic heating range up to ~35 °C; the actual value depends on insulation and the initial room temperature.

What room area corresponds to each model?

UKE-AS2000M — up to 25 m²; UKE-AS1500M — approximately up to 20 m²; UKE-AS1000M — approximately up to 15 m² with standard insulation.

How much electrical energy does the convector consume?

Hourly consumption corresponds to the installed power under continuous heating (e.g., ~2 kWh for 2000 W). With the thermostat, actual consumption is lower and depends on conditions.

.

May I use an extension cord?

Yes, provided the extension cord is rated for the device power and is not loaded with other appliances. The outlet and wiring must be appropriate in cross-section and current rating.

Where is the power cord located, and what is its length?

The cord exits on the right (when facing the front panel), length about 1.2 m.

Is there an operation indicator?

Yes, power and heating indicators are provided.

Are voice control and smartphone control supported?

No. Control is mechanical: thermostat and rotary regulator.

How should I install the heater: on the floor or on the wall?

Both floor and wall installation are allowed. The set includes feet and brackets; castors are not included.

Can it be mounted on a wooden wall or plastic panels?

Yes, if installation requirements, thermal clearances, and absence of moisture exposure are observed. The base must be strong and heat-resistant.

May I place the convector on a glazed balcony?

Yes, in a dry, glazed room with normal ventilation. Do not operate or store the unit in the presence of condensate or at sub-zero temperatures without packaging.

What are the off-season storage requirements?

Store in the manufacturer’s packaging in a heated, ventilated room at +1…+40 °C and average relative humidity up to 80 % at +25 °C.

Is around-the-clock operation in winter permissible as primary heating?

The convector is designed for prolonged operation and automatic temperature maintenance. For safety reasons, it is not recommended to leave the unit unattended for extended periods or if any malfunction is suspected.

Why does the convector click or briefly “restart”?

Clicks are normal operation of the thermostat and thermal deformation of metal during heating/cooling. Brief shutoff indicates protection or thermostat activation.

Is it normal for the rear panel to heat up?

Yes. The metal rear panel participates in heat exchange and may heat noticeably; observe spacing from the wall as per the instructions.

May I dry items on the convector or cover it?

No. Covering the unit or placing objects closer than 10 cm is prohibited—this disrupts heat exchange and may cause overheating.

What do overheat protection and the “Restart” function mean?

Thermal protection switches off heating in the event of overheating. “Restart” automatically restores operation with prior settings after a brief power interruption.

What is the moisture protection class, and may it be used in a bathroom/shower?

The models are intended for dry rooms (the moisture protection class depends on the version and installation conditions). Operation in areas with splashes and condensate is not recommended; avoid water contact with the housing.

Why is there an odor or slight “smoke” at first power-on?

A temporary reaction of the heater’s factory coating may occur during the first hours of operation; this is short-lived and disappears after warm-up.

.

Is it safe to mount in an anteroom (pre-banya)?

Permissible only in the absence of direct moisture and condensate, observing clearances and electrical safety norms.

What are the dimensions and weight of the models, and example sizes?

Example for the 2000 W version: dimensions about 830x400x83 mm, mass ~4.4 kg. Exact dimensions depend on the modification.

Does the convector dry the air?

Like any electric heater, it reduces relative humidity during heating. Ventilation and use of a humidifier are recommended if necessary.

Can the thermostat be fully bypassed for continuous heating?

No. Disabling the thermostat is prohibited—it will lead to overheating and loss of safety.

Does it spark upon switching off, and what should I do if a visible spark appears?

A slight thermostat click is normal. If a spark is visible, switch off the device, check the mains and connectors; if repeated, contact service.

Can the “Umnyi Vybor” convector be used as an alternative to an oil-filled radiator?

At identical power, long-term heat output is comparable. The convector heats air faster; an oil radiator retains heat longer after switch-off.

Is there tip-over protection?

For floor installation, structural stability measures are provided; place on a flat surface and do not block air inlets/outlets.

What clearances must be observed during installation?

Minimum distance from objects — at least 10 cm; do not block the upper and lower grilles to ensure free convection.

Can the convector be used in a country house without permanent heating?

Yes, provided the room is dry and the temperature does not fall below 0 °C. Before switching on after long storage in the cold, allow the unit to equilibrate at room temperature for at least 2 hours.

How to protect the convector from voltage fluctuations?

It is recommended to connect the device through a surge protector or voltage stabilizer, especially with an unstable power grid.

How should I clean the housing and grilles of the convector?

Disconnect the unit from the mains, allow it to cool, and clean the housing with a soft dry or slightly damp cloth. Do not use abrasives and do not allow water to enter the housing.

.

Is it necessary to clean the interior of the unit?

Under normal operation, it is sufficient to remove dust from the surface and ventilation openings. In case of significant contamination, service by a service center is recommended.

Can the convector be used for room drying?

Yes, brief use to reduce humidity is possible, but operation is not permitted in the presence of condensate or splashes on the housing.

What is the correct way to switch off the heater?

Turn the thermostat to the minimum position, wait for the thermostat click, then switch off the power toggle (if provided) and unplug the power plug.

May the unit be left on overnight?

Permissible with a functional thermostat and compliance with safety rules: do not cover the unit, keep away from furniture and curtains, and do not use in rooms with high humidity.

What is the surface temperature of the housing during operation?

The temperature of metal parts may reach 80–90 °C. This is normal; however, touching the grilles and covering the housing are prohibited.

What materials are used in the construction?

The housing is made of painted steel panels with heat-resistant coating; the heating element is a metal STICH needle type; feet and brackets are made of heat-resistant plastic.

What is the noise level during operation?

The convector operates virtually silently; only occasional thermostat clicks and minor sounds of thermal expansion are audible.

May multiple convectors be connected to one outlet?

No. Each unit must be connected to a separate branch or outlet rated for the corresponding load current.

What humidity is permissible during operation?

Recommended relative humidity — no more than 80 % at temperatures up to +25 °C. Increased humidity may cause condensate and insulation damage.

How can I determine that overheat protection has tripped?

In case of overheating, the unit switches off automatically. After cooling, the temperature decreases and heating resumes without user intervention.

May I use an extension cord with a switch?

Yes, if rated for at least 2 kW and providing a reliable contact. Ensure that the plug and socket do not heat during operation.

May the heater be placed under a window or near curtains?

Yes, installation under a window is permissible subject to safe clearances: at least 10 cm on top and sides, and at least 5 cm from the floor.

How long does the unit take to reach operating temperature?

Full warm-up to nominal operation takes about 5–10 minutes depending on ambient temperature.

How do I know that the convector is on?

The unit has a power indicator. During heating, the lamp is on; when the set temperature is reached, it turns off.

May I block the rear grille?

No. Disruption of air circulation will lead to overheating and protective shutdown.

.

Why might the heater switch off before the room warms up?

The thermostat responds to the air temperature near the housing, not at the center of the room. For more uniform heating, install the unit where air circulation is good.

May I paint the housing?

No. Any change to the coating may degrade heat transfer and lead to overheating. Use the unit only with the factory coating.

What is the energy efficiency class of the convector?

The device belongs to the standard energy efficiency class for domestic electric heaters. The energy conversion coefficient is close to 100 %, losses are minimal.

Is the convector suitable for use in a child’s room?

Yes, when wall-mounted and with safe clearances observed. The housing has no exposed heating elements and produces no odors under normal operation.

May the convector be used in an office or industrial setting?

Yes, the device is suitable for heating residential and administrative premises, including offices, utility, and production rooms with normal humidity and without dust or chemical vapors.

What is the ambient operating temperature range?

Operation is recommended at air temperatures from +1 °C to +40 °C. At lower temperatures, condensate and insulation damage are possible.

May several convectors be installed in one room?

Yes, provided the electrical wiring is adequate and total power is calculated. Each unit must be connected to a separate outlet.

Is power regulation available?

Stepwise power regulation is not provided—the unit is controlled solely by the thermostat, which switches heating on and off depending on temperature.

What are the power supply requirements?

Single-phase supply 220–230 V, 50 Hz. The outlet must have a grounding contact and withstand a load current up to 10 A for 2000 W models.

May I connect the unit via a smart socket?

Yes, if the socket is rated for at least 10 A and supports the corresponding load. Temperature control in this case is still performed by the unit’s built-in thermostat.

What conductor cross-section is required for connection?

For power up to 2000 W, a copper conductor cross-section of at least 1.5 mm² is recommended.

Is there built-in protection against voltage surges and short circuits?

Built-in electronic surge protection is not provided. Use of an external voltage stabilizer or RCD is recommended to enhance safety.

May the unit be connected through a circuit breaker?

Yes, connection through a 10 A circuit breaker is recommended, corresponding to the network characteristics and device power.

What air temperature can the thermostat maintain?

The adjustment range is typically from +5 °C to +35 °C, depending on the model. When the set temperature is reached, heating stops automatically.

.

Why does the unit not switch on?

Check the mains connection, outlet integrity, and thermostat position. If overheat protection has tripped, wait for the unit to cool.

Why does the convector fail to heat the air to the required temperature?

Possible reasons: insufficient power for the room area, poor insulation, drafts, incorrect thermostat setting, or clogged grilles.

May the device be used together with other heaters?

Yes, combined use with other heating systems is permissible provided electrical safety is observed and the total network load is calculated.

What is the service life of the device?

The average service life is at least 5 years, subject to operating and maintenance rules. The heating element is designed for long-term operation without loss of capacity.

May the device remain plugged in with the thermostat switched off?

Yes, with the thermostat off, heating does not occur, but it is recommended to disconnect the unit from the mains for safety and energy saving.

How does short-circuit protection work?

Built-in thermal protection switches the unit off in case of overheating, but it does not replace external protective devices. For reliability, use an external circuit breaker.

May the unit be installed in a niche or under furniture?

No, installation in confined spaces is prohibited. Free air circulation is necessary for correct convection.

How does installation height affect heating efficiency?

Optimal placement is 10–15 cm above the floor. When installed higher, efficiency decreases because warm air rises.

May the unit be operated without feet by simply placing it on the floor?

No. The device must be installed on the standard feet or brackets to ensure stability and an air gap underneath.

What is the procedure for initial commissioning?

Before first switch-on, ensure the housing is intact, place the unit on a flat surface, connect to the mains, and gradually set the desired temperature. A slight new-coating odor may appear and will dissipate within a few hours.

Instructions user for climate equipment

Arctic Air Ultra Mini air conditioner Manual
Convector BALLU BEC/EZER -1000 -1500 -2000 Manual
Air cooler Blyss AC51 Manual
Fan Xiaomi Mijia Tower Fan 2 (BPTS02DM) Manual
Manual Thermometer HTC-1
Manual weather station Ea2