User manual for the remote control of the split-system LERAN LR-07 / LR-09 / LR-12 / LR-18 / LR-24



LERAN LR Split-System Remote Control Manual

LERAN LR Split-System Remote Control. Operating Instructions

GZ-1002B-E3 Air Conditioner Compatibility

The remote control is compatible with:

LERAN LR Series Air Conditioners

Models:
LR 07 LR  LR 01 P10
LR 09 L3  LR 09 P10
LR 12 L3  LR 12 P10
LR 18 L3
LR 24 LR

Safety Precautions

• The remote control is not a toy. Do not allow children to play with it and do not play with it yourself.

• When using the remote control, point its signal emitter at the indoor unit of the air conditioner when pressing buttons. The indoor unit will confirm signal reception with a short beep.

• Signals can be received up to 8 meters away in a straight line from the indoor unit at an angle of 45° to the left and right. There should be no obstacles between the remote control and the unit for proper signal transmission.

• The remote control should be kept at least 1 meter away from television and radio equipment.

• Do not drop the remote control or subject it to strong impacts. Protect it from direct sunlight, heat sources, water, and high humidity.

• Do not use sharp objects to press the buttons to avoid damage. Do not clean the remote with gasoline, solvent, chemically treated wipes, etc.

• If the remote control does not function properly, remove the batteries, wait 30 seconds, and then reinsert them. If the problem persists, replace the batteries.

(!) Remove the batteries from the remote control if it will not be used for an extended period.

(!) Attention! The manufacturer reserves the right to make changes to the design, configuration, or manufacturing technology of the remote control without prior notice to the customer.

.

Description of Remote Control Buttons for LERAN LR

The provided image shows a standard remote control with all functional buttons. They may slightly differ from the buttons on your remote control (depending on the model).

LERAN LR Split-System Remote Control Manual

1. Operating Display

Displays the current mode and parameters.

2. Operating Mode

[ AUTO ] - automatic mode
[ COOL ] - cooling mode
[ DRY ] - dehumidification mode
[ FAN ] - ventilation mode
[ HEAT ] - heating mode

3. Temperature Adjustment

A single press changes the temperature by 1°C. Temperature adjustment range: 16–31°C.

4. ON/OFF

Turns the unit on/off.

.

5. FAN SPEED

Selects the fan speed of the indoor unit.

Successive presses change the fan speed in the following sequence:
Low – medium – high – automatic.

6. SLEEP

Used during sleep time. Pressing the button either enables or disables this function. Works only in Cooling, Dehumidification, and Heating modes.

7. SWING

Changes the direction of the airflow. Pressing the button either enables or disables this function.

8. MANUAL

Manual adjustment of airflow direction.

Successive presses change the louver angle incrementally.

LERAN LR Split-System Remote Control Manual

9. ON TIMER

This button is used to enable the ON Timer function.

10. OFF TIMER

This button is used to enable the OFF Timer function.

11. SET TIMER

Saves the set values.

12. CANCEL TIMER

Clears the set values.

.

13. REMOTE CONTROL RESET

Reset your remote control by connecting these two points with a metal object if it does not respond to button presses.

(!) NOTES:
- The HEAT mode is available only in systems equipped with this function.
- The effective operating distance of the remote control is 6 meters in a straight line without interference.
- If the remote control will not be used for a long period, remove the batteries.
- In this illustration, all functions are shown on the display simultaneously for clarity. On some models, certain functions shown on the display may not appear.
- Do not expose the batteries to any mechanical or thermal impacts, as this may cause the remote control to fail.

OPERATING MODES

Automatic ON/OFF Function by Timer (Preset Time)

A. To set automatic shutdown of an operating air conditioner using the timer, press the OFF button on the wireless remote control. The icon → ◯ will start flashing on the display.

To set automatic startup of a switched-off air conditioner, press the ON button on the remote control. The icon → I will start flashing on the display.

B. Each press of the ON or OFF button increases the startup or shutdown time by 1 hour (maximum value – 12 hours). This information will be displayed on the screen.

C. To confirm the set ON/OFF time, press the SET button. The icon on the remote control will stop flashing.

Canceling the Preset Automatic ON/OFF Timer

To cancel a previously set automatic ON/OFF time, press the CANCEL button on the remote control. The icon → ◯ or → I will disappear from the remote control display.

(!) NOTES:
- If there was a power outage, the automatic ON/OFF time will be lost and needs to be set again.
- After the automatic ON/OFF time has been set and confirmed by pressing the SET button, it can only be changed by canceling with the CANCEL button and setting it again.
- If, after the automatic ON/OFF time has been set and confirmed by the SET button, the SET button is pressed again, the countdown will restart.

.

Operating Modes – Parameter Adjustment

AUTO Mode

In this mode, the air conditioner will automatically maintain a comfortable indoor temperature. After switching on, the air conditioner will begin operating in one of the following modes, depending on the room temperature (see table):

Room Temperature (RT)Air Conditioner Mode
RT ‹ 20°CHeating (for units without heating function – Dehumidification)
20°C ‹ RT ‹ 24°CFan
RT › 24°CCooling

COOLING Mode

Press the MANUAL SWING or SWING button to change the vertical airflow angle or to activate the swing mode.

The airflow speed is adjusted by pressing the FAN SPEED button on the remote control.

Temperature is adjusted using the temperature control buttons on the remote control within a range of 16–31°C.

DRY Mode

In this mode, the air conditioner automatically sets the indoor temperature. The temperature value is not shown on the display. Temperature and airflow speed cannot be adjusted in this mode.

FAN Mode

In this mode, the outdoor unit does not operate.

The airflow direction can be adjusted using the MANUAL SWING and SWING buttons.

Fan speed can be adjusted using the FAN SPEED button.

HEAT Mode

The airflow direction can be adjusted using the MANUAL SWING and SWING buttons.

The airflow speed is adjusted using the FAN SPEED button.

Temperature is adjusted using the temperature control buttons on the remote control within a range of 16–31°C.

SLEEP Mode

SLEEP Mode during cooling and dehumidification:

1. The fan operates at the lowest speed.

2. After 1 hour of operation, the maintained temperature increases by 1°C. After another hour, the temperature rises by another 1°C. In total, the temperature increases by 2°C and remains at that level.

SLEEP Mode during heating:

1. The fan operates at the lowest speed.

2. After 1 hour of operation, the maintained temperature decreases by 2°C. After another hour, the temperature drops by another 2°C. In total, the temperature decreases by 4°C and remains at that level.

.

Battery Installation / Replacement

LERAN LR Split-System Remote Control Manual

• Remove the battery compartment cover by sliding it in the direction indicated by the arrow.

• Insert new batteries, ensuring the (+) and (-) terminals are positioned correctly.

• Close the battery compartment cover by sliding it back into place.

(!) NOTE:
• Replace the batteries if the LCD display of the remote control is not lit or when the remote control cannot be used to adjust the air conditioner settings.
• Use new LRO 3 AAA 1.5 V batteries (mini-size).
• Do not use rechargeable batteries.
• Used batteries must be disposed of in accordance with the regulations of the country of use.
• If the remote control will not be used for more than a month, remove the batteries.

Indoor Unit LCD Display

LERAN LR Split-System Remote Control Manual

1. SLEEP mode indicator
2. Automatic ON/OFF timer mode indicator
3. FAN mode indicator
4.1. In normal mode, displays the room temperature
4.2. When changing the temperature in COOLING or HEATING mode, flashes to show the set temperature. After 10 seconds, returns to room temperature display mode.
4.3. When setting the timer, shows the set time. After 10 seconds, returns to room temperature display mode.
4.5. If a system error occurs, the LCD displays the fault code
5. HEAT mode indicator
6. DRY mode indicator
7. COOL mode indicator
8. Remote control signal receiver

Error Codes (Displayed on the LCD)

No.CodeFaultCauseExplanation and Troubleshooting
1A0No power supplyPhases are reversed or one phase is missingIdentify the cause and correct the wiring.
2C0Control circuit faultControl circuit wire not connectedSecurely connect the control circuit wires.
3C1Data transmission error between indoor and outdoor unitsData transmission signal form issueContact the nearest service center.
4E1Room temperature sensor faultRoom temperature sensor is faultyDisconnect power, check sensor connection, replace faulty sensor.
5E2Indoor unit heat exchanger temperature sensor faultSensor is faultyDisconnect power, check sensor connection, replace faulty sensor.
6E4Outdoor unit heat exchanger temperature sensor faultSensor is faultyDisconnect power, check sensor connection, replace faulty sensor.
7H1Outdoor unit faultOutdoor unit malfunctionDetermine the cause based on outdoor unit display signals.
8H2Overload protection activation – high compressor pressureExcessively high outdoor temperature; blocked air intake; dirty air filterIdentify and eliminate the cause.
9H3Overload protection activation – low compressor pressureExcessively low outdoor temperature; significant refrigerant leakage; low pressure at compressor inletIdentify and eliminate the cause.
10P1Indoor unit anti-freeze protection activatedIndoor unit heat exchanger freezingWait, auto recovery
11P2Indoor unit overheat protection activatedIndoor unit overheatingWait, auto recovery
12P3Outdoor unit overheat protection activated in cooling modeProtection system triggeredWait, auto recovery
13FFSystem failed to startProtection system triggeredTurn the system off and on again.
14P6Outdoor air too cold in heating modeProtection system triggeredWait, auto recovery
15P7Outdoor unit heat exchanger icing in heating modeProtection system triggeredWait, auto recovery
16PSCompressor crankcase heater operation indicatorCompressor protection system triggeredWait, auto recovery
17CFDirty filter indicatorFilter contaminationDisconnect power and clean the filters.
.

NOTE

If the system is additionally equipped with a wall-mounted wired control unit, this unit can receive signals from the wireless remote control. The display of such a unit may show the following errors:

No.FaultLight Indication
1Power supply voltage failureSequence of 1 flash with a 3-second delay
2Outdoor unit heat exchanger temperature sensor faultSequence of 4 flashes with a 3-second delay
3Compressor overload protection triggeredSequence of 5 flashes with a 3-second delay
4Compressor overload protection triggered due to high pressureSequence of 6 flashes with a 3-second delay
5Compressor overload protection triggered due to low pressureSequence of 7 flashes with a 3-second delay
6Outdoor unit compressor protection triggeredSequence of 8 flashes with a 3-second delay

EMERGENCY MODE

If the control unit indicates a malfunction, there is an emergency shutdown button on the indoor unit of the air conditioner. Pressing this button switches the air conditioner as follows:

AUTO mode → COOLING mode → STOP

(!) NOTE:
If the control unit is switched on, the emergency shutdown button will not function. To use this button, the control unit must be removed, and then the air conditioner must be turned off and on again.

User manuals for climate remote controls

GZ-50GB-E1 Air Conditioner Remote Control Manual
Universal Air Conditioner Remote HUAYU ClickPdu K-1303E Manual
Grundig GRHPA/GRFPO Air Conditioner Remote Control Manual
General Climate R11 H/G Split-System Remote Control Manual
Kentatsu KIC-111H Air Conditioner Remote Control Manual
Huayu Q-1000E Air Conditioner Remote Control Manual