User manual for the remote control of the split-system GZ01-BEJ0-000



Remote control for split-system GZ01-BEJ0-000 Manual

Remote Control for Split-System GZ01-BEJ0-000. Operating Instructions

GZ01-BEJ0-000 Air Conditioner Remote Control Compatibility

The GZ01-BEJ0-000 remote control is compatible with:

Galanz KUDO Series Wall-Mounted Air Conditioners (R410A refrigerant)

GIOWI09RK3
GIOWI12RK3

GIOWI09RK16
GIOWI12RK16
GIOWI18RK16
GIOWI24RK16

GIWI09RK3/16 - Inverter
GIWI12RK3/16 - Inverter
GIWI18RK16 - Inverter
GIWI24RK16 - Inverter

Galanz VIVA Series Wall-Mounted Air Conditioners (R22 refrigerant)

GIOW07RV5
GIOW09RV5
GIOW12RV5
GIOW18RV8
GIOW24RV8

GIOW07RG24
GIOW09RG24
GIOW12RG24
GIOW18RG24
GIOW24RG2
GIOW30RG2
GIOW36RG2

Galanz GALAXY Series Wall-Mounted Air Conditioners (R22 refrigerant)

GIW24RG2
GIW30RG2
GIW36RG2

\
Galanz SEMI-INDUSTRIAL AIR CONDITIONERS Indoor Units Cassette Type (R410A refrigerant)

GC-18HRT/U
GC-24HRT/U
GC-36HRST/U
GC-48HRST/U

Galanz SEMI-INDUSTRIAL AIR CONDITIONERS Indoor Units Floor-Ceiling Type (R410A refrigerant)

GU-12HRT/AU
GU-18HRT/AU
GU-24HRT/AU
GU-36HRST/AU
GU-48HRST/AU
GU-60HRST/AU

Galanz SEMI-INDUSTRIAL AIR CONDITIONERS Indoor Units Duct Type (R410A refrigerant)

GD-18HMRT/U
GD-24HMRT/U
GD-36HMRST/U
GD-48HMRST/U
GD-60HMRST/U

GD-36HTRS/U
GD-48HTRS/U
GD-60HTRS/U

Precautions

- The remote control is not a toy. Do not allow children to play with it.
- When using the remote control, point it towards the indoor unit of the air conditioner. A short beep confirms that the signal has been received.
- The remote control signal is received at a distance of up to 8 meters in a straight line from the indoor unit at an angle of 45° to the left and right. There must be no obstacles between the remote control and the unit.
- Keep the remote control at least 1 meter away from televisions and radios.
- Do not drop the remote control or expose it to impacts. Protect it from sunlight, heat, water, and high humidity.
- Do not use sharp objects to press the buttons. Do not clean the remote control with gasoline, solvent, or chemically treated wipes.
- If the remote control does not work, remove the batteries, wait 30 seconds, and reinsert them. If this does not help, replace the batteries.

(!) - Important! Remove the batteries if the remote control will not be used for an extended period.

(!) - Attention! The manufacturer reserves the right to make changes to the design, configuration, or manufacturing technology of the remote control without prior notice.

\

Description of the GZ01-BEJ0-000 Remote Control Buttons

The image shows a standard remote control with all functional buttons indicated. Depending on the model, the buttons on your remote control may differ slightly.

Remote control for split-system GZ01-BEJ0-000 Manual

1. Operating Display

Displays the current mode and settings.

2. Operating Mode

[ AUTO ] - automatic mode
[ COOL ] - cooling mode
[ DRY ] - dehumidification mode
[ FAN ] - ventilation mode
[ HEAT ] - heating mode

3. Temperature Adjustment

Pressing the button once changes the temperature by 1°C. Temperature adjustment range: 16–31°C.

4. ON/OFF

Turns the unit on or off.

\

5. FAN SPEED

Selects the fan speed of the indoor unit.

Each press of the button changes the fan speed in the following sequence:
Low – Medium – High – Automatic.

6. SLEEP

Used during sleep. Pressing the button either enables or disables this function. Operates only in Cooling, Dehumidification, and Heating modes.

7. SWING

Airflow direction oscillation mode. Pressing the button either enables or disables this function.

8. MANUAL

Manual adjustment of the airflow direction.

Each press of the button changes the louver position by a specific angle:

Remote control for split-system GZ01-BEJ0-000 Manual

9. ON TIMER

This button is used to activate the ON Timer function.

10. OFF TIMER

This button is used to activate the OFF Timer function.

11. SET TIMER

Stores the set values.

12. CANCEL TIMER SETTINGS

Clears the set values.

\

13. REMOTE CONTROL RESET

Reset your remote control by connecting these two points with a metal object if it does not respond to button presses.

(!) NOTES:
- Heating mode is only available in systems equipped with this function.
- The effective operating distance of the remote control is 6 meters in a straight line without interference.
- If the remote control will not be used for a long time, remove the batteries.
- In the illustration, all functions are shown on the display simultaneously for demonstration purposes. On some models, certain functions shown on the display may not be available.
- Do not subject the batteries to mechanical or thermal impact, as this may cause the remote control to fail.

OPERATING MODES

Automatic On/Off Function by Timer (Preset Time)

A. To set the automatic shutdown of an operating air conditioner using the timer, press the OFF button on the wireless remote control. The → ◯ icon will start flashing on the display.

To set the automatic start of a switched-off air conditioner, press the ON button on the remote control. The → I icon will start flashing on the display.

B. Each press of the ON or OFF button on the remote control increases the ON or OFF time by 1 hour (maximum value — 12 hours). This information will be displayed on the screen.

C. To confirm the set ON/OFF time, press the SET button. The icon on the remote control will stop flashing.

Canceling the Preset Automatic On/Off Timer

To cancel the previously set automatic ON/OFF time, press the CANCEL button on the remote control. The → ◯ or → I icon will disappear from the display.

(!) NOTES
- If there was a power outage, the automatic ON/OFF time will not be saved and must be set again.
- After the automatic ON/OFF time has been set and confirmed by pressing the SET button, it can only be changed by canceling it with the CANCEL button and setting it again.
- If, after the automatic ON/OFF time has been set and confirmed by pressing the SET button, the SET button is pressed again, the countdown will restart.

.

Operating Modes — Parameter Adjustment

AUTOMATIC Mode — AUTO

In this mode, the air conditioner will automatically maintain a comfortable indoor temperature. After switching on, the air conditioner will operate in one of the following modes depending on the room temperature (see table):

Room Temperature (RT)Air Conditioner Mode
RT ‹ 20°CHeating (for air conditioners without heating function — Dehumidification mode)
20°C ‹ RT ‹ 24°CFan RT › 24°C Cooling

COOLING Mode

Press the MANUAL SWING or SWING button to change the vertical airflow angle or switch to oscillation mode.

The airflow speed is adjusted by pressing the FAN SPEED button on the remote control.

The temperature is adjusted using the temperature control buttons on the remote control within the range of 16 to 31°C.

DEHUMIDIFICATION Mode — DRY

In this mode, the air conditioner automatically sets the indoor temperature. The temperature value is not displayed. Temperature and airflow speed adjustment is not available in this mode.

FAN Mode

In this mode, the outdoor unit does not operate.

The modes and airflow direction can be adjusted using the MANUAL SWING and SWING buttons.

The fan speed can be adjusted using the FAN SPEED button.

HEATING Mode — HEAT

The airflow direction can be adjusted using the MANUAL SWING and SWING buttons.

The airflow speed is adjusted using the FAN SPEED button.

The temperature is adjusted using the temperature control buttons on the remote control within the range of 16 to 31°C.

SLEEP Mode

SLEEP Mode in Cooling and Dehumidification Modes:

1. The fan operates at the lowest speed.

2. After 1 hour of operation, the maintained temperature increases by 1°C. After another hour, the temperature increases by another 1°C, for a total increase of 2°C, and is maintained at that level.

SLEEP Mode in Heating Mode:

1. The fan operates at the lowest speed.

2. After 1 hour of operation, the maintained temperature decreases by 2°C. After another hour, the temperature decreases by another 2°C, for a total decrease of 4°C, and is maintained at that level.

\

Liquid Crystal Display (LCD) of the Indoor Unit

Remote control for split-system GZ01-BEJ0-000 Manual

1. SLEEP mode indicator
2. Automatic ON/OFF timer mode indicator
3. FAN mode indicator
4.1. In normal mode, displays the room temperature
4.2. While adjusting the temperature in COOLING or HEATING mode, blinks to display the set temperature. After 10 seconds, returns to room temperature display mode.
4.3. While setting the timer, displays the set time. After 10 seconds, returns to room temperature display mode.
4.5. If a system malfunction occurs, the LCD displays an error code
5. HEATING mode indicator
6. DEHUMIDIFICATION mode indicator
7. COOLING mode indicator
8. Remote control signal receiver

Error Codes (Displayed on the LCD)

No.CodeFaultCauseDescription and Troubleshooting
1A0No power supplyPhases are mixed or one phase is missing.Identify the cause and correct the wiring.
2C0Control circuit faultControl circuit wire not connectedSecurely connect the control circuit wires.
3C1Data transmission error between indoor and outdoor unitsData transmission signal form issueContact the nearest service center.
4E1Room temperature sensor malfunctionRoom temperature sensor malfunctionDisconnect power, check the sensor connection, replace the faulty sensor.
5E2Indoor unit heat exchanger temperature sensor malfunctionSensor malfunctionDisconnect power, check the sensor connection, replace the faulty sensor.
6E4Outdoor unit heat exchanger temperature sensor malfunctionSensor malfunctionDisconnect power, check the sensor connection, replace the faulty sensor.
7H1Outdoor unit malfunctionOutdoor unit malfunctionIdentify the cause based on the outdoor unit display signals.
8H2Overload protection triggered — high compressor pressureExcessively high outdoor temperature; blocked air intake; dirty air filterIdentify and eliminate the cause.
9H3Overload protection triggered — low compressor pressureExcessively low outdoor temperature; significant refrigerant leak; low pressure at the compressor inletIdentify and eliminate the cause.
10P1Indoor unit anti-freeze protection activatedIndoor unit heat exchanger icingWait, automatic recovery
11P2Indoor unit overheating protection activatedIndoor unit overheatingWait, automatic recovery
12P3Cooling mode — outdoor unit overheating protection activatedProtection activatedWait, automatic recovery
13FFSystem failed to startProtection activatedSwitch the system off and on.
14P6Outdoor air too cold in heating modeProtection activatedWait, automatic recovery
15P7Outdoor unit heat exchanger icing in heating modeProtection activatedWait, automatic recovery
16PSCrankcase heater operation indicatorCompressor protection activatedWait, automatic recovery
17CFDirty filter indicatorFilter contaminationTurn off the system and clean the filters.
\

NOTE

If the system is additionally equipped with a wall-mounted wired control panel, this panel can receive signals from the wireless remote control. The display of such a panel may show the following errors:

No.FaultLight Indicator
1Power supply failureSequence of 1 flash with a 3-second pause
2Outdoor unit heat exchanger temperature sensor malfunctionSequence of 4 flashes with a 3-second pause
3Compressor overload protection activatedSequence of 5 flashes with a 3-second pause
4Compressor overload protection — high pressureSequence of 6 flashes with a 3-second pause
5Compressor overload protection — low pressureSequence of 7 flashes with a 3-second pause
6Outdoor unit compressor protection activatedSequence of 8 flashes with a 3-second pause

EMERGENCY MODE

If the control unit indicates a malfunction, the indoor unit of the air conditioner has an emergency shutdown button. Pressing this button switches the air conditioner as follows:

AUTO Mode → COOLING Mode → STOP

(!) NOTE
If the control unit is switched on, the emergency shutdown button does not work. To operate the button, it is necessary to remove the control unit, then turn the air conditioner off and on.

User Manuals for Climate Remote Controls

GZ-50GB-E1 Air Conditioner Remote Control Manual
Universal Air Conditioner Remote Control HUAYU ClickPdu K-1303E Manual
Grundig GRHPA/GRFPO Air Conditioner Remote Control Manual
LERAN LR -07 -09 -12 -18 -24 Remote Control Manual
Kentatsu KIC-111H Air Conditioner Remote Control Manual
Huayu Q-1000E Air Conditioner Remote Control Manual